9.5.2 Shore power

The boat can be equipped with shore power.

Energised AC system

Electric shock may cause death or serious injury.

Disconnect the shore power when it is not in use.

Verify the system is de-energised before performing any work.

Power cable contact with water

Connecting the shore power cable may energise the water around the boat and cause death or serious injury to nearby swimmers.

Do not allow any part of the power cable to hang in the water.

Note the following when using shore power.

  • Connect metallic housings or enclosures of installed electrical appliances to the protective conductor system in the boat.

  • Only use double-insulated or grounded (earthed) electrical appliances.

  • Do not alter shore power cable connectors. Only compatible cable connectors and shore power receptacles.

  • Test the operation of the RCD (Residual Current Device) monthly.

When the shore power is connected, the boat’s electrical equipment is mainly powered via shore power. On boats equipped with an inverter, the inverter automatically switches to battery power when the power demand exceeds the incoming shore power capacity.

Boats not equipped with inverter have a dedicated charger for main batteries and service batteries. This allows the batteries to be charged when the shore power is connected. The chargers are located next to the batteries and are accessible via the service hatch at the bottom of the pilot house seat boxes.